Manual_CANopen_StrainLink_EN_V3_05.doc

57/65

Baumer

22.07.11/dam

Frauenfeld, Switzerland

Transmission of serial number:

ID

DLC

Byte1

Byte2

Byte3

Byte4

Byte5

Byte6

Byte7

Byte8

7E5

8

43h

7Bh

00h

00h

00h

0

0

0


Serial number:
Byte 1:

43h

System byte serial number

Byte 2 – 5:

7B’00’00’00h

00’00’00’7B (LSB first)

123


Response from CANopen strain link:

ID

DLC

Byte1

Byte2

Byte3

Byte4

Byte5

Byte6

Byte7

Byte8

7E4

8

44h

0

0

0

0

0

0

0


The strain link confirms the identification with the answer. Now the ID and baud rate of the sensor can be
changed

7.5.5

Changing ID and baud rate

Set of new ID:

ID

DLC

Byte1

Byte2

Byte3

Byte4

Byte5

Byte6

Byte7

Byte8

7E5

8

11h

01h

0

0

0

0

0

0


Example ID = 1:
Byte 2:

01h

ID = 1


Response from CANopen strain link:

ID

DLC

Byte1

Byte2

Byte3

Byte4

Byte5

Byte6

Byte7

Byte8

7E4

8

11h

00h

0

0

0

0

0

0


Byte 2:

00h

ID successfully changed

01h

ID beyond valid range

FFh

specific failure