2. Electrical Data


Operating temperature range

0 to +50

O

C

(32 to 122 F)

Storage temperature range

-20 to +70

O

C

(-4 to 158 F)

Humidity during operation, rel.

80%

Humidity during storage, rel.

90%


Operating voltage U

B

DC 19,2V . . . 28,8V (DC 24V +/- 20%)


Operating current, max.
without

load

150

mA

all

LEDs

on

180

mA


Handwheel

Operating voltage (internal)

DC 5V +/-5%

Output

circuit

according

to

RS

422A

Outputs, galvanically isolated

A, /A, B, /B


Serial data interface

RS

422A

Data format

8 Data bit + 1 Parity bit (even), 1 or 2 Stop bit

Baud rate

9600 or 19200 Baud, selectable via DIL switch

Transfer protocol

leant to procedure 3964R


DIL

switch

S1

1 2 3 4

19200

Baud

OFF OFF OFF OFF

9600 Baud

ON

OFF OFF

OFF default

Contrast LCD:
turning Potentiometer
clockwise = brighter



Potentiometer

DIL switch S1





Advertising