10. LC-Display


The LCD operates in text mode.

The PLC transfers style attributes and content of the displayed message.

Frequently used messages will be transferred to the HBLS during an initialising routine and
stored in the data memory (RAM). These messages can then be displayed by a short
command.


Command to the LCD:

PLC:

STX

LCD

Data

block

DLE

ETX

BCC

LCD:

DLE

DLE


Acknowledge:

PLC:

DLE

DLE

LCD:

STX

LCD

Acknowledge

block DLE ETX BCC


Each data block, which includes a command for the LCD (in contrast to push-buttons or
selector switches) has to have a LCD identifier byte as the first sign:

Hex 0x6C / ASCII "small-l".



A data block can include several commands with a maximum length of 128 Bytes.



LCD Acknowledge block:


After being adapted, each command has to be acknowledged with the LCD Acknowledge
block. During this procedure, the HBLS is able to handle push buttons and LED commands.
A further LCD data block can only be sent after the LCD Acknowledge block.

The acknowledge block includes the LCD identifier byte and an additional Status-Byte.

Status-Bytes:

0x31 command okay

0x32

no

defined

text

selected

0x33

no

defined

area

selected

0x34

illegal

parameter





Hint: After a status check (request the actual status), the LCD Acknowledge block is no
longer sent.