3 command overview, Installation, Mechanical dimensions – EUCHNER HBLS 072725 Benutzerhandbuch
Seite 42

EUCHNER Pendant station HBLS 072725
067018-08-01/06
Subject to technical modifications
page 20 / 22
10.3 Command Overview
Command
Byte
Description Parameter
0x21
cursor to the next character
0x22
cursor to the previous character
0x23
cursor to the next lower line
0x24
cursor to the upper line
0x25
cursor to the LCD home position
0x26
cursor to the beginning of the line
0x27
cursor to a defined position
line (0x30...37),
column(0x30..3F)
0x28
Delete at actual cursor position
0x29
Delete up to line end
0x2A
Delete up to display end
0x2B
Delete whole display
0x2C
Delete part of the screen
Start-line, -column,
End-line, -column
0x40
Inverse on, all following characters will be
displayed inverse
0x41 Inverse
off
0x42
Flash on, all following characters will be displayed
flashing
0x43 Flash
off
0x48
Text definition
Text-number, line, column,
text
0x49
Display defined text
Text-number
0x4A Definition
of
area
Area-number,
Start-line, Start-column,
End-line, End-column
0x4B
Delete defined area
Area-number
0x4C
Inverse displayed area
Area-number
0x4D
Flashing displayed area
Area-number
0x4E
Inverse and Flashing displayed area
Area-number
0x4F
Standard displayed area
Area-number
11. Installation
To ensure, the EMC protection requirements are fulfilled, the connecting cable has to be
shielded.
The shield of the mounted cable of the HBLS is el. connected to the connector housing.
The user has to fit a metal flange connector and its case has to be grounded.
All extending lines (serial communication interface, counter modules, enabling switches, E-
Stop) have also to be shielded and grounded at a central grounding point at the control.
Suitable RS 422-receiver circuits are necessary for the transmission of the handwheel
signals A; /A and B; /B (e.g. 75176).
It is not permitted to use TTL level signals (only A and B, without /A or /B).
The serial communication interface requires an RS 422A transmitter circuit and an RS 422A
receiver circuit.
For the correct choice of the wire diameters, the whole cable length is to be calculated.