10.1.5 Area Commands

With one short command, the user can define up to 32 areas, which can be deleted, inverted
or displayed flashing. The actual attribute will not be changed.

Command Byte Description

Parameter

0x4A

Definition of area

Area-number, start-line, start-
column, end-line, end-column

0x4B

Delete defined area

Area-number

0x4C

Inverse displayed area

Area-number

0x4D

Flashing displayed area

Area-number

0x4E

Inv. and flashing displayed area

Area-number

0x4F

Standard displayed area

Area-number


Area-numbers: from 0x31 (area 1) to 0x51 (area 32).
If a non-defined area will be called, a acknowledge protocol with 0x33 will be sent.

Example of a data block, which defines the area-no. 22 from line 4, column 0 to line 6,
column 10:

0x6C 0x4A 0x46 0x34 0x30 0x36 0x3A


Example of a data block, which deletes area-no. 22:

0x6C 0x4B 0x46


Example of a data block, which displays area-no. 22 flashing:

0x6C 0x4D 0x46