page 9 / 22

7. LED on/off


The LEDs can be switched on/off or set up to flash separately.

The PLC tells the pendant which LED has to be switched on or off.

HBLS

PLC


Byte

1

STX

(02H)

Byte 1

DLE

Byte

2

LED-Byte

(see

table)

Byte 3

DLE

(10H)

Byte

4

ETX

(03H)

Byte 5

BCC

Byte 2

DLE





LED

on

off

flashing LED

Layout


LED

1

31H

41H

51H

LED

2

32H

42H

52H

LED

3

33H

43H

53H

LED

4

34H

44H

54H

LED

5

35H

45H

55H

LED

6

36H

46H

56H

LED

7

37H

47H

57H

LED

8

38H

48H

58H

LED

9

39H

49H

59H

LED

10 3AH

4AH

5AH

LED

11 3BH

4BH

5BH

LED

12 3CH

4CH

5CH


all

LEDs

30H

40H

50H







1 2 3 4
5 6 7 8
9 10 11 12