Probes for air

Note: Because of the high response accuracy, the use of thermowells (pockets) is not admissible.

Actual type designation

Old type
designation

Probe type

Temperature range

Nom. length mm

P

rocess connection

RTD temperature probe Data Sheet 90.2006

902006/65-228-1003-1-15-500-668/000

-

1 x Pt100

-170 ... +700°C

500

902006/65-228-1003-1-15-710-668/000

-

710

902006/65-228-1003-1-15-1000-668/000

-

1000

902006/55-228-1003-1-15-500-254/000

-

1 x Pt100

-170 ... +700°C

500

902006/55-228-1003-1-15-710-254/000

-

710

902006/55-228-1003-1-15-1000-254/000

-

1000

902006/65-228-2003-1-15-500-668/000

90.271-F01

2 x Pt100

-170 ... +700°C

500

Stop flange,
movable

902006/65-228-2003-1-15-710-668/000

90.272-F01

710

902006/65-228-2003-1-15-1000-668/000

90.273-F01

1000

902006/55-228-2003-1-15-500-254/000

-

2 x Pt100

-170 ... +700°C

500

movable
G1/2 compression
clamp

902006/55-228-2003-1-15-710-254/000

-

710

902006/55-228-2003-1-15-1000-254/000

-

1000

Thermocouples Data Sheet 90.1006

901006/65-547-2043-15-500-668/000

90.019-F01

2 x NiCr-Ni, Typ

E „K“

-35 ... +800°C

500

Stop flange,

movable

901006/65-547-2043-15-710-668/000

90.020-F01

710

901006/65-547-2043-15-1000-668/000

90.021-F01

1000

901006/65-546-2042-15-500-668/000

90.019-F11

2 x Fe-CuNi, Typ

E „L“

-35 ... +700°C

500

901006/65-546-2042-15-710-668/000

90.020-F11

710

901006/65-546-2042-15-1000-668/000

90.021-F11

1000

901006/66-550-2043-6-500-668/000

90.023-F01

2 x NiCr-Ni, Typ

E „K“

-35 ... +1000°C

500

901006/66-550-2043-6-355-668/000

90.023-F02

355

901006/66-550-2043-6-250-668/000

90.023-F03

250

901006/66-880-1044-6-250-668/000

90.021

1 x PT10Rh-PT, Typ

E „S“

0 ... 1300°C

250

901006/66-880-1044-6-355-668/000

90.022

355

901006/66-880-1044-6-500-668/000

90.023

500

901006/66-880-2044-6-250-668/000

90-D-021

2 x PT10Rh-PT, Typ

E „S“

0 ... 1300°C

250

Stop flange,

movable

901006/66-880-2044-6-355-668/000

90-D-022

355

901006/66-880-2044-6-500-668/000

90-D-023

500