Target modules
»
CATpro2-VT100
G&D CompactCenter X2 · 35
Technical Data
Graphics
Signal type:
analog, RGBHV
Resolution:
800 × 600 or 1024 × 768 pixels
Display area:
40 to 139 columns, 24 to 48 rows
Interfaces
for matrix switch:
1 × RJ45 socket
for serial device:
1 × D-Sub 9 socket
Emulation
Protocol:
VT100, VT420pc, linux, solaris,
x11r5 (XFree 3.x.x), default (XFree 4.x.x)
History:
2.000 characters
Serial interface
Signal type:
RS232-C
Transmission rate:
max. 115.200 bps
Transmitted signals:
TxD, RxD, DTR, DSR, RTS, CTS, GND (DCD, RI as
outpute in DCE mode)
Parity:
none, even or odd
Data bits:
5 to 8
Stop bits
1 or 2
Data flow control:
none, hardware (RTS/CTS),
software (XON/XOFF)
Update
Mode:
local service socket
Power supply
Type:
table power pack
Connection:
miniDIN-4 Power socket
Voltage:
AC100-240V/60-50Hz
Casing
Dimensions:
104 × 26 × 84 mm (W × H × D)
Weight
ca. 210 g
Operating environment Temperature:
+5 to +45 °C
Air humidity:
20 - 80%, non-condensing