3 system requirements, 4 restrictions for devices of the el 100 series, System requirements – Lenze VisiWinNet VisiWinNET Smart Benutzerhandbuch
Seite 141: Restrictions for devices of the el 100 series, Preface and general information, Smart

Preface and general information
System requirements
l
141
SHP−VWNS DE/EN 6.1
1.3
System requirements
In order to be able to work with VisiWinNET
â
Smart, the hardware and software must,
according to our experience, meet the following requirements:
Hardware
minimum
recommended
Computer
IBM−compatible PC
CPU family
Intel Pentium/Celeron
CPU clock frequency
500 MHz
1 GHz or higher
RAM
256 MB
512 MB or higher
Graphics
800 x 600 pixels, High Color (16 bit)
1280 x 1024 pixels, True Color
(32 bit)
Free hard−disc space
200 MB for development system
280 MB for .Net−Framework (if not yet installed)
DVD drive
Only for installation
Ports
l
Ethernet or CAN interface for communication with the target device
(optionally free COM or USB terminal).
l
Free USB terminal for hardware dongle
Software
Operating system
Windows Server, XP SP2 or Vista
Applications
Microsoft .NET Framework (in the scope of supply if not already installed)
Optional applications
*)
l
Microsoft .NET Compact Framework 2.0 SP1,
l
Microsoft .NET Framework SDK 2.0
l
PDF Reader (for user manuals)
l
Internet browser (for online help)
l
Microsoft ActiveSync.
*)
Optional software products that are not available on the installation computer can be ordered free of charge via the
Internet pages of the corresponding manufacturers. If these products are not installed, some advanced functions of
VisiWinNET
â
Smart are not available. For installation, additional free memory space on the hard disk is needed.
1.4
Restrictions for devices of the EL 100 series
For performance reasons, in the case of HMIs of the EL 100 series there are the following
restrictions in VisiWinNET
â
Smart :
Function
EL 106 ... EL 110s
EL 105 / EL 103 ECO
Maximum number of variables
1000
500
Minimum scanning time of a
communication group
100 ms
200 ms
Maximum number of alarms
2000
1000
Alarm history, binary ring buffer
With a maximum of 1000 alarms
With a maximum of 500 alarms
Trends
l
Max. 20 trends
l
Min. scanning time 500 ms
l
Max. 50 trend files during
runtime
l
Min. cache size 10
l
2000 samples per file
l
Max. 10 trends
l
Min. scanning time 1000 ms
l
Max. 50 trend files during
runtime
l
Min. cache size 10
l
2000 samples per file
Logging
System is completely deactivated and cannot be re−activated, even by the
user
Recipes
l
Max. 500 variables per recipe
l
Max. 50 recipe files during
runtime
l
Max. 250 variables per recipe
l
Max. 50 recipe files during
runtime