Configuration
Communication
Configure CAN connection via codes
l
232
SHP−VWNS DE/EN 6.1
Browsing variables
5. Highlight the CAN channel in Project Explorer, right−click it and select Browse
variables.
VWNS−035
6. Click Add and fill in the "Configure device" dialog.
VWNS−036
Communication type: Communication type "VisiWinNET LenzeCAN Driver"
Device path: CAN node address of the fieldbus node with which data is to be
exchanged.
Parameter file: EDS/GDC file for the import of variables
For importing codes via a GDC file, you always need a pdb file that matches the device
for which the GDC file has been created. The pdb files are stored in the main GDC
directory in the folders pdb/049 (German) and pdb/044 (English).
Device alias: Enter any name you like.
7. Close the dialog with OK.