44

Operatingandcommissioning

8.6.5

configuring the outputs (general diagram)

OUtPUt

AO1

0......9

DO1

PULSE

hYStERES.

wiNDOw

wARNiNG

DO2

DO3

REtURN

hYStERES.

wiNDOw

Parameterizing the 4-20 mA analogue output, AO1. See chap.
“8.6.6”.

Configuring the transistor output DO1 as a pulse output. See
“Figure 36”, chap. “8.6.8”.

Configuring the transistor output DO1 to switch a load
depending on two threshold values. See “Figure 39” and
“Figure 38”, chap. “8.6.8”.

If the device is equipped with relays, configuring the relay
output DO2 or DO3 to switch a load depending on two
threshold values. See “Figure 39”, chap. “8.6.8” and “Figure
42”
chap. “8.6.12”.

Configuring the transistor output DO1 to switch a load when a
warning message is generated by the device. See “Figure 41”
chap. “8.6.8”.

wARNiNG

If the device is equipped with relays, configuring the relay
output DO2 or DO3 to switch a load when a warning message
is emitted by the device. See “Figure 43” chap. “8.6.12”.

0......9

0......9

Activate / deactivate the generation of a 22 mA current on the
AO1 current output, when the device generates a fault. See
chap. “8.6.7”.

4MA-20MA

ERR. 22MA.

0......9

FiLtER

REtURN

Figure 33:

Diagram of the "OUTPUT" parameter of the Parameters menu

8.6.6

Associating a flow rate range to the current output Ao1

The 4-20 mA output provides an electrical current, the value of which reflects the flow rate measured by the
device.

Example of relation between the measuring range and the current output:

4

20

20

180

mA

l/min

English

Type 8025 UNIVERSAL