Proline Promass 80 PROFIBUS PA

Identification

11

2.1.3

Nameplate for connections

a0001665

Fig. 4:

Nameplate specifications for Proline sensor (example)

1

Serial number

2

Possible configuration of current output

3

Possible configuration of relay contacts

4

Terminal assignment, cable for power supply: 85 to 260 V AC, 20 to 55 V AC, 16 to 62 V DC
Terminal No. 1: L1 for AC, L+ for DC
Terminal No. 2: N for AC, L- for DC

5

Pending signals at the inputs and outputs

→ Page 91 ff.

possible configuration and terminal assignment

6

Version of device software currently installed (inclusive language group)

7

Installed communication type

8

PROFIBUS ID No.

9

Date of installation

10

Language group

11

Current updates to data specified in points 6 to 9

Communication:

Drivers:

Device SW:

ID XXXX (HEX)

XX.XX.XX

PROFIBUS PA

Date:

DD MMM YYYY

Ex works / ab Werk / réglages usine:

26(+)

/

27(-)

NC:

Versorgung /

Tension d'alimentation

Observer manuel d'instruction

See operating manual
Betriebsanleitung beachten

26 = PA +
27 = PA -

PROFIBUS PA (Profile 3.0)

XXXXXXXXXXX

Ser.No.:

Supply /

24(+)

/

25(-)

22(+)

/

23(-)

20(+)

/

21(-)

N / L-

PE

A:

NO:

P:

L1 / L+

1

2

FEK1512–2

X

active
passive

normally open contact

normally closed contact

Update 1

Update 2

2

3

1

4

5

6
7
8
9

10

(WEA)