Calculation example for gas, Recommended full scale values, Operable flow range – FMC Corporation - Talstar 80 Benutzerhandbuch

Seite 91: Input signal, Status input: technical data, 4 output, Output signal, Signal on alarm, Profibus pa interface, 5 power supply

Advertising
background image

Proline Promass 80 PROFIBUS PA

Technical data

91

Calculation example for gas:

• Sensor type: Promass F, DN 50
• Gas: air with a density of 60.3 kg/m³ (at 20 °C and 50 bar)
• Measuring range (liquid): 70000 kg/h
• x = 90 (for Promass F DN 50)

Max. possible full scale value:
g

max(G)

=

g

max(F)

·

ρ

(G)

÷ x [kg/m³] = 70000 kg/h · 60.3 kg/m³ ÷ 90 kg/m³ = 46900 kg/h

Recommended full scale values

See information on

→ Page 101 ff. ("Limiting flow")

Operable flow range

Greater than 1000 : 1. Flows above the preset full scale value do not overload the amplifier, i.e.
totalizer values are registered correctly.

Input signal

Status input (auxiliary input):

U = 3 to 30 V DC, R

i

= 5 k

Ω, galvanically isolated.

Configurable for: positive zero return, error message reset, zero point adjustment start, batching
start/stop (optional), totalizer reset for batching (optional).

10.1.4

Output

Output signal

• PROFIBUS PA in accordance with IEC 61158 (MBP), galvanically isolated
• Profile Version 3.0
• Data transmission rate: 31.25 kBaud
• Current consumption: 11 mA
• Permitted supply voltage: 9 to 32 V
• Bus connection with integrated reverse polarity protection
• Error current FDE (Fault Disconnection Electronic): 0 mA
• Signal coding: Manchester II
• Bus address can be configured via miniature switches, via the local display (optional) or operating

program

Signal on alarm

PROFIBUS PA interface:

Status and alarm messages in accordance with PROFIBUS Profile Version 3.0

10.1.5

Power supply

Electrical connections

→ Page 26 ff.

Supply voltage

85 to 260 V AC, 45 to 65 Hz
20 to 55 V AC, 45 to 65 Hz
16 to 62 V DC

Cable entries

Power supply and signal cables (inputs/outputs):
• Cable entry M20 x 1.5 (8 to 12 mm)
• Threads for cable entries, ½" NPT, G ½"

Connecting cable for remote version:
• Cable entry M20 x 1.5 (8 to 12 mm)
• Threads for cable entries, ½" NPT, G ½"

Advertising