Turning the local display

1.

Unscrew cover of the electronics compartment from the transmitter housing.

2.

Press the side latches on the display module and remove the module from the electronics
compartment cover plate.

3.

Rotate the display to the desired position (max. 4 x 45 ° in both directions), and reset it onto
the electronics compartment cover plate.

4.

Screw the cover of the electronics compartment firmly back onto the transmitter housing.

a0003236

Fig. 20:

Turning the local display (field housing)

3.4

Post-installation check

Perform the following checks after installing the measuring device in the pipe:

4 x 45°

Device condition and specifications

Notes

Is the device damaged (visual inspection)?

-

Does the device correspond to specifications at the measuring point, including
process temperature and pressure, ambient temperature, measuring range, etc.?

→ Page 7 ff.

Installation

Notes

Does the arrow on the sensor nameplate match the direction of flow through the
pipe?

-

Are the measuring point number and labeling correct (visual inspection)?

-

Is the orientation chosen for the sensor correct, in other words suitable for sensor
type, fluid properties (outgassing, with entrained solids) and fluid temperature?

→ Page 14 ff.

Process environment / process conditions

Notes

Is the measuring device protected against moisture and direct sunlight?

-