Promass h, Promass i, Promass p – FMC Corporation - Talstar 80 Benutzerhandbuch

Seite 114: Seals, Promass f, e, h, i, s, p, Promass m, Promass a, Material load diagram, Process connections, 11 human interface

Advertising
background image

Technical data

Proline Promass 80 PROFIBUS PA

114

Promass H:

• Zirconium 702/R 60702

Promass I:

• Titanium grade 9
• Titanium grade 2 (flange disks)

Promass P:

Stainless steel 1.4435/316L

Seals:

Promass F, E, H, I, S, P:

Welded process connections without internal seals

Promass M:

Viton, EPDM, silicon, Kalrez 6375, FEP sheathing (not for gas applications)

Promass A:

Welded process connections without internal seals.
Only for mounting sets with threaded connections: Viton, EPDM, silicon, Kalrez

Material load diagram

The material load diagrams (pressure-temperature diagrams) for the process connections are
provided in the separate "Technical Information" document on the device in question. This can be
downloaded as a PDF file from www.endress.com.
A list of the "Technical Information" documents available is provided on

→ Page 116

Process connections

see Page 112 ff.

10.1.11 Human interface

Display elements

• Liquid crystal display: illuminated, two lines with 16 characters per line
• Selectable display of different measured values and status variables
• At ambient temperatures below –20 °C (–4 °F) the readability of the display may be impaired.

Operating elements

• Local operation with three keys (–, +, E)
• Quick Setup menus for straightforward commissioning

Language groups

Language groups available for operation in different countries:

• Western Europe and America (WEA):

English, German, Spanish, Italian, French, Dutch and Portuguese

• Eastern Europe and Scandinavia (EES):

English, Russian, Polish, Norwegian, Finnish, Swedish and Czech.

• South and East Asia (SEA):

English, Japanese, Indonesian

!

Note!
You can change the language group via the operating program "FieldCare".

Remote operation

Operation via PROFIBUS