Gb 3. specifications – WIKA UPT-21 Benutzerhandbuch

Seite 11

Advertising
background image

11

WIKA operating instructions process transmitter, model UPT-2x

14068347.01 06/2014 GB/D

GB

3. Specifications

3.2 Accuracy data

Accuracy at reference conditions

Including non-linearity, hysteresis, zero offset and end value deviation (corresponds to

measured error per IEC 61298-2).

Accuracy

Standard

0.15 % of span

Option 1

0.10 % of span

Option 2

0.20 % of span

Mounting correction

-20 ... +20 %

Non-repeatability

≤ 0.15 % of span

Behaviour with turndown (with accuracy 0.15 %)

Turndown = basic measuring range : scaled measuring range

1:1 ... 5:1 No change in accuracy

> 5:1

< 0.03 % x turndown

Long-term stability

≤ (0.1 % x turndown)/year

Thermal change zero point/span (reference temperature 20 °C)

In compensated range 10 ... 70 °C:

< 0.05 % / 10 K x turndown

Outside compensated range:

Typical < 0.1 % / 10 K x turndown

Thermal change of the current output (reference temperature 20 °C)

< 0.05 % / 10 K, max. 0.15 %