Hypertherm MAX200 Machine Torch Plasma Arc Cutting System Benutzerhandbuch
Seite 140

Max200 Timing Chart
Con1
Main Contactor
V1
Plasma Pre/Post flow solenoid valve
V2
Shield gas solenoid
V3
Plasma step gas solenoid valve
V4
Cap-On-Sense solenoid valve
V9
Plasma charging valve
PB1
Power On switch
PB2
Power Off switch
PS3
Plasma gas outlet pressure switch. N.O. switch that
closes when the plasma gas pressure exceeds 3 psi.
PS4
Quick charge pressure switch. N.C. switch that opens
when plasma gas reaches 26 psi.
Start
Plasma start signal from CNC
Stop
Plasma stop signal from CNC
Xfer
Arc Transfer
Post-Flow 1 second gas flow at end of cycle.
Note:
1. In test mode, V1, V2, and V3, are the only valves that are active.
2. When V1 becomes active after start, 10 to 15 psi will be registered
at PG1.
3. The HV transformer is activated 2 seconds after the plasma start
signal. It will stay active for 5 seconds or until the arc transfers to
the work piece, which ever happens first.