Max200 Timing Chart

Con1

Main Contactor

V1

Plasma Pre/Post flow solenoid valve

V2

Shield gas solenoid

V3

Plasma step gas solenoid valve

V4

Cap-On-Sense solenoid valve

V9

Plasma charging valve

PB1

Power On switch

PB2

Power Off switch

PS3

Plasma gas outlet pressure switch. N.O. switch that
closes when the plasma gas pressure exceeds 3 psi.

PS4

Quick charge pressure switch. N.C. switch that opens
when plasma gas reaches 26 psi.

Start

Plasma start signal from CNC

Stop

Plasma stop signal from CNC

Xfer

Arc Transfer

Post-Flow 1 second gas flow at end of cycle.

Note:

1. In test mode, V1, V2, and V3, are the only valves that are active.
2. When V1 becomes active after start, 10 to 15 psi will be registered

at PG1.

3. The HV transformer is activated 2 seconds after the plasma start

signal. It will stay active for 5 seconds or until the arc transfers to
the work piece, which ever happens first.