ALTANA Temp-Chart Benutzerhandbuch

Seite 86

Advertising
background image

temp-gard Hardware temp-chart Software

9

Standard Barriers


Cat. No. 3321 – Standard

Dimensions

Height Width Length Weight

Weight

incl.

temp-gard

165

mm

(6.5 in)

240 mm

(9.4 in)

255 mm

(10 in)

6.8 kg

(15 lbs)

7.5 kg

(16.6 lbs)


Temp.

°C +100 +150 +200 +250 +300

Duration in
Hours*

9 6 4 3 1


* These values are only valid for a completely cooled down heat barrier with cooled down
heat sinks.

Please note, due to continuing product development, specifications are subject to change
without prior notice.


Measurement Time

Number of

Sensors

Sampling Interval in Seconds

1 2 5

10

8

427 min

853 min

2133 min

4267 min

7

480 min

960 min

2400 min

4800 min

6

549 min

1097 min

2743 min

5486 min

5

640 min

1280 min

3200 min

6400 min

4

768 min

1536 min

3840 min

7680 min

3

960 min

1920 min

4800 min

9600 min

2

1280 min

2560 min

6400 min

– –

1

1920 min

3840 min

9600 min

– –


Please note: Due to continuing product development specifications are subject to change
without prior notice.