2 communication, 1 transfer project via lan to el1xx, Communication – Lenze VisiWinNet VisiWinNET Smart Benutzerhandbuch

Seite 229: Transfer project via lan to el1xx, Configuration

Advertising
background image

Configuration

Communication

Transfer project via LAN to EL1xx

5

l

229

SHP−VWNS DE/EN 6.1

5.2

Communication

The VisiWinNET

â

Smart scope of supply includes several example projects that have been

copied to your hard disk during the program installation.

These projects can be used to get to know VisiWinNET

â

Smart and, moreover, to check the

PC

«operating unit EL1xx connection and the readiness for operation of the operating

unit.

Prepare the following to control e.g. a servo inverter by means of the EL1xx and the
example project:

Drive

What to do

Procedure

9400 servo inverter

l

Make the basic configuration and select the
"Actuating drive − speed" application

l

Assign CAN node address 2 (C0350)

l

Transmit project to the controller

l

Enable controller and activate fixed setpoint 1

^ Engineer Online Manual

5.2.1

Transfer project via LAN to EL1xx

Precondition: The network connection between the PC and EL1xx has been set up and is
active (

^ User instructions for the HMI EL1xx, chapter entitled "Setting up an Ethernet

connection"). An application running on the target device must be ended.

Proceed as follows:

1. Go into Project Explorer and open the folder Project configurationand then open the

subfolder Target device.
The "Configuration (target device)" Properties page is shown.

2. Open the Transfer tab.

3. Selection the TC/IP connection in the selection field Transfer settings.

Advertising