Configuration

Communication

Configure CAN connection via PDOs

5

l

235

SHP−VWNS DE/EN 6.1

Configure channel

Prerequisite:

ƒ

The EL1xx is connected via LAN to the PC on which VisiWinNET

â

Smart has been

installed.

ƒ

The EL1xx is connected to the controller via CAN.
For more information, please read the documentation for the EL1xx and the controller.

Proceed as follows:

1. Go into Project Explorer and create a new channel: Highlight the Variables /

Channels folder, right−click it and then select New.

2. In the line OPC−Server/Driver, click [...] and then select the LenzeCAN

communication driver.

3. Close the dialog with OK.

The channel is created and displayed in the project tree.

4. Double−click the new channel in the object tree and configure it on the Properties

page.