Configuration

Communication
Configuring the L−force Logic (CoDeSys) connection

5

l

242

SHP−VWNS DE/EN 6.1

VWNS011

5.2.5

Configuring the L−force Logic (CoDeSys) connection

Via VisiWinNET

â

Smart V 6.2 (or higher), an "EL1xx PLC" can communicate with an L−force

Logic (CoDeSys) application.

Precondition:

ƒ

VisiWinNET

â

Smart and L−force Logic (CoDeSys) have been installed on the same PC

or on different PCs that are connected to each other via LAN.

Configuring a channel

Proceed as follows:

1. Go into Project Explorer and create a new channel: Highlight the Variables /

Channels folder, right−click it and then select New.

2. In the line OPC−Server/Driver, click [...] and select CoDeSys.

3. Close the dialog with OK.

The channel is created and displayed in the project tree.

4. Double−click the new channel in the object tree and configure it on the Properties

page.