Gb 3. specifications, 3 electrical separation of the connections – WIKA DI25 Benutzerhandbuch

Seite 13

Advertising
background image

13

WIKA operating instructions digital indicator, model DI25

14076218.01 12/2013 GB/D

GB

3. Specifications

3.3 Electrical separation of the connections

Ground terminal

insulated

Power supply

A1 output

insulated

A2 output or trans-

mitter power supply

insulated

A3 output

insulated

insulated

insulated

insulated

CPU

non-insulated

Input

HOLD Input

insulated

Serial communication

Actual value output

insulated

Insulation resistances: ≥ 10 MΩ for DC 500 V

Insulation test:

AC 1.5 kV for 1 minute between input and ground

AC 1.5 kV for 1 minute between input and power supply

AC 1.5 kV for 1 minute between power supply and ground

AC 1.5 kV for 1 minute between output and ground

AC 1.5 kV for 1 minute between output and power supply

Output includes alarm outputs A1, A2, A3, the analogue actual-

value output signal and the serial interface.

3.4 Dimensions in mm

PV

SV

HOLD

A1

A2

A3

A1

A2

A3

DI25

FAST

MODE

48

96

106,2

Dichtung

Schraubbügel

11,5

98,5

44,5

Sealing

Screw type

mounting bracket

Advertising