14 usb sun keyboard layout, 15 temperature warning, Usb sun keyboard layout – Guntermann & Drunck CATVision Benutzerhandbuch

Seite 116: 15 temperature, Warning

Advertising
background image

Guntermann & Drunck GmbH

Operating Instructions
CATVision (MC)

page 42

6.2.2.14

USB SUN Keyboard layout

After activation of the USB SUN Keyboard mode (see above) you can use this
menu item to select the keyboard layout of the SUN keyboard.

If you experience that german umlauts and other language-specific characters
are without correct output at screen, check this adjustment and modify if
necessary.

The following options are available:

DE: German keyboard layout

US: American keyboard layout


If the adjustment of the keyboard layout is modified during the operation of the
SUN computer, a restart of the SUN computer is necessary, in order to apply
the modified adjustment.

At default modifying of this adjustment is not possible, because the support for
USB SUN keyboards is deactivated.

6.2.2.15 Temperature Warning

Both the user module (CATVision-CON) and the computer module (CATVision-
CPU) provide temperature sensors. The temperature within the devices is
permanently monitored.

To prevent the modules from overheating, the following actions are performed
when the stated values are achieved:

60 °C: The modules show the increased temperature values in the OSD or as

display popup (see below).

80 °C: The image signal is disabled at the user module!

Important: If the computer module disables the image signal due to the increase

of temperature, the connected computers cannot be controlled or operated
remotely! Cool down the heated module immediately after the warning has been
displayed on your screen!

The warning is displayed at

both modules after the temperature of one of the

modules reaches a critical value. The warning states whether the overheating
affects the user module (remote unit) or the computer module (local unit).

Important: There is no warning if the temperature of the second module

reaches a critical value while the first module also provides increased
temperature values!