2 calling up the ivt mode, Calling up the ivt mode – Guntermann & Drunck CATVision Benutzerhandbuch

Seite 94

Advertising
background image

Guntermann & Drunck GmbH

Operating Instructions
CATVision (MC)

5.4.2

Calling up the IVT Mode

The IVT mode can be called up in two ways (Default):

via function menu

CTRL & NUM

via

hotkey

CTRL & Scroll

.

The following window opens:

I V T
A c t i v e c h a n n e l : 1

C V M

Boost

4

Noise filter

0

Fine tuning

36

delay R

delay G

delay B

0 ns

0 ns 0 ns

ESC: quit IVT menu
F1: save and quit
F3: copy to all channels
1/2/3/4: select channel
F5: auto adjust active channel
F6: auto adjust all channels


The IVT menu can be called up from the remote or the local console. Settings
within the IVT menu, however, are only possible via remote console. IVT
settings from the local console can only be proceeded by the administrator.

If a user from the local console wants to change the settings the following
window opens:

I n f o

C V M


IVT is only available

on remote console.

Press ESC to return.

By pressing

ESC

you will get back to the last active menu.