Operation

14 · G&D FIBREVision

Operation

The computer connected to the computer module (FIBREVision-CPU) can be oper-

ated at the remote console of the user module and at the local console of the com-

puter module.

After both consoles have been initiated, they are enabled to operate the computer.

Concurrent operation of the FIBREVision system

If a user carries out a keyboard or a mouse input, the FIBREVision system automati-

cally locks the input devices of the concurrent console. The lock is lifted if no inputs

are made at the active console during the adjusted timing of the automatic input

lock (default: 1 second).

After the automatic input lock has been lifted, both consoles are again able to operate

the computer.

As an alternative to operate the computer concurrently through the consoles, the

exclusive operation (see below) can also be activated.

Related topics:

Changing the timeout of the automatic input lock on page 28

Changing the videomode of the user consoles on page 30

Exclusive operation of the FIBREVision system

For operating the FIBREVision system exclusively, the function Authorising permanent

activation of input lock can be activated in the setup menu.

If this function is switched on, the user of the FIBREVision system can activate the exclu-

sive operation by pressing the key combination

Hotkey+PrtScr

(default:

Ctrl+PrtScr

).

After having pressed this key combination, the input devices of the concurrent con-

sole are deactivated. By pressing the key combination again at the console where the

permanent input lock has been activated, users at both consoles are again able to

operate the FIBREVision system.

After the permanent input lock has been activated at one console, the Scroll LEDs

are blinking on the keyboards of both consoles.

Related topics:

Changing the timeout of the automatic input lock on page 28

Changing the videomode of the user consoles on page 30

NOTE:

In the default setting, the monitors of both the remote and the local console

of the FIBREVision system always display the same picture at the same time – inde-

pendently from the input lock.
The paragraph Changing the videomode of the user consoles on page 30 explains how

this setting can be changed.