2-2. rear panel – Sony SIR-3400H Benutzerhandbuch

Seite 39

Advertising
background image

(E)

3-19

SIR-3400H / SIR-3032i / SIR-3032W

3-2-2. Rear Panel

1

TO EXPMAIN/EXP connector
Used to connect with a recording unit or SIF-3004 (measuring unit expansion board).

2

DIP switches
These switches are used to make measuring unit settings.

SW1 to SW3 : These set the initial EXP No. of the measuring unit.

SW

EXP No.

Maximum number of

1

2

3

effective channels

OFF

OFF

OFF

1

32

ON

OFF

OFF

2

64

OFF

ON

OFF

3

128

ON

ON

OFF

4

128

OFF

OFF

ON

Reserve

Reserve

ON

OFF

ON

Reserve

Reserve

OFF

ON

ON

Reserve

Reserve

ON

ON

ON

Reserve

Reserve

SW4 to SW8 : Disabled
SW8

: This sets the calibration function.

DISABLE: Disables the calibration function.
ENABLE : Enables the calibration function (factory setting).

3

OUTPUT connectors
Used to output analog signals.
Connect BNC cables (sold separately) to the corresponding connectors.
When there are multiple measuring units, the channels are put in order starting from the smallest EXP
No.

<Example> Channel assignments for two 32-channel measuring units

EXP No. 1 : Channels 1 to 32
EXP No. 2 : Channels 33 to 64

Power supply block

Analog output connectors

1

3

2

3. Names and Functions of Parts