12-3

SIR-3400H / SIR-3032i / SIR-3032W

12-5. Setting the Input Range

(Modes: STOP, E-E, REC-PAUSE, and REC)

The input range value of the recording amplifier is set for each channel.
Set using either Manual or Auto.

Manual setting : The range values are set manually from the setting values.
Auto setting

: The range values are automatically set by the recording unit based on the input signal

level.

n
In case the DC-coupling direct input format is set

(See [12-7. Setting the Input Format]):

When the unnecessary DC components are contained in the input signal, it is recommended to set the input
range after canceling the DC components with the input DC offset.

12-5-1. Setting the Manual Range

1

Press the RANGE key.
The M lamp at the top left of the key and the channel number in the MONITOR display area flash. The
The Range indicator appears in the setting value display area.

2

Use the g / G key to select the target channel.

Setting value : EXP. UNIT

1 to 4, A/B

MONITOR

1 to 32

3

Use the f / F key to select the input range value.

Setting value

10 V

5 V

2 V

1 V

0.5 V

0.2 V

0.1 V

Input range (Vpk)

±10

±5

±2

±1

±0.5

±0.2

±0.1

Range values and bar meter scale
Example : When 10 V is set:

The bar meter scale becomes

±100 % or 0 dB when the input voltage is +10 Vpk, _10 Vpk,

or

±10 Vpk.

. Pressing the F1 key applies the settings to all channels of the current channel group (A or B).
. Pressing the F2 key enables the channel setting to be checked on a list. Press the F4 key to return to the

original screen.

4

Press the RANGE key. The settings are completed.

When not in setting mode, the f, F, g, and G keys can be used to change the monitor channel.

f / F key : Every 16 channels
g / G key : Every channel

12. Operation Settings (Using Setting key)