SIR-3400H / SIR-3032i / SIR-3032W

12-11. Setting the Test Signal

(Modes: E-E, REC-PAUSE, and REC)

This procedure enters a preset test signal to all channels.

1

Press the SHIFT key, and then press the OUT/TSG key.
The lamp at the top right of the key flashes. The Test Signal indicator appears in the setting value display
area.

2

Use the f / F key to change the test signal value.

Setting value : AC

±100 %, DC +100 %, DC _100 %, 0 V

3

Press the OUT/TSG key.
The settings are completed.

12-12. Mark Settings

(Modes: All)

Marks can be added to any two selected locations. These recording positions can be searched.

Pressing the MRK1 or MRK2 key saves the record position at that data position.
c
. Mark2 can be set even when there is no Mark1.
. If the Mark1 and Mark2 are pressed when settings have already been made for Mark1 and Mark2, the new

Mark position replaces the old setting.

12-13. Panel Lock

(Modes: All)

1

Hold down the SHIFT key for at least two seconds.
The Panel Lock state is set (key operation is disabled), and the PNL LOK lamp turns on.

Canceling Panel Lock
Hold down the SHIFT key for at least two seconds in the Panel Lock state. This cancels Panel Lock, and the
PNL LOK lamp turns off.

12. Operation Settings (Using Setting key)