Please read carefully the following precautions prior to use. These precautions will
prevent your data on recording media from being damaged or lost.

Condensation

In the default settings, the condensation sensor on this unit is set to off.
(1) Always turn the condensation sensor on under conditions where condensation may form easily such as

when the temperature around the recording unit goes from a low to high temperature.

(2) To prevent damage to data in environments where condensation tends to occur, be sure to always eject

the recording media after using the recording unit, and then press the POWER switch to turn off the
power.

<Reference> (Section 7-2-2)
Off : Condensation is not detected. If condensation occurs the recording media and data may become damaged.
On : Condensation is detected when the unit’s power is turned on to protect the recording media and data

from being damaged.

Warming Up/Cooling Down

When the temperature inside the unit is too high or too low, the unit displays one of the following messages
and the unit is automatically cooled down or warming up. The unit cannot be operated until the temperature
reaches proper level and the message on LCD display disappears.

LCD message

Recording unit status

Remarks

Low Temp Warming Up

Internal temperature < 5

dC

Displayed until the internal temperature is
5

dC or higher

High Temp Cooling Down 70

dC < Internal temperature

Displayed until the internal temperature is less

than 70

dC

Overwrite

Once overwritten, the previously recorded data after the point where the overwriting ends cannot be reproduced
(see section 2-5).

<Reference> (Section 8-2-3)
Overwriting is prohibited in the default settings.
To cancel the overwrite protection, set the Overwrite option under Utility_Global Setup Menu_Function to
On in the LCD screen.
In an attempt of overwriting, a message “Overwrite?” will appear on the LCD of the recording unit. If you
wish to overwrite the old data, press FWD key with REC key pressed down.

Power Switch

When turning off the unit completely, first confirm that the ACCESS lamp is out and then turn off the
POWER switch on the rear of unit.