8-3

SIR-3400H / SIR-3032i / SIR-3032W

8. Function Setup (Function Screen)

8-2-4. Selecting the Trigger Mode (Trigger Mode)

Factory setting: Single

* For the setting procedure, see “8-1. Setting Procedure (for Function Screen)”.

Settings

Single : During trigger recording, recording starts when the trigger input signal changes from High to

Low, and recording continues until the STOP key is pressed.

Multi : During trigger recording, recording starts when the trigger input signal changes to Low, and

recording stops when it changes to High.

8-2-5. Pre-Trigger Recording On/Off (Pre-Trigger)

Factory setting: Off

* For the setting procedure, see “8-1. Setting Procedure (for Function Screen)”.

<When set to On>
During trigger recording, data before the trigger is recorded. Data length (s) before trigger is automatically
changes depending on to the recording media speed.

<When set to Off>
During trigger recording, and data is recorded immediately after the trigger.

8-2-6. IRIG-B Timecode On/Off (IRIG)

Set this switch to On to calibrate the internal clock by inputting the IRIG-B time code to the AUX analog
channel. When set to Off, the internal clock is not calibrated with the IRIG-B time code.

Factory setting: On