40 - 1110

DIGITAL INDUSTRIAL CONTROLLER

english

6.3

Process operation

In the process operation level, the 6 operator controls have the meanings shown in
Figure 23.

Meaning

Operator control

MANUAL/AUTO key

Switching over the MANUAL and AUTOMATIC modes.
The AUTOMATIC mode is indicated by an LED in the operator
control.

Switch-over to the next process variable
SP:

Set-point

PV:

Actual value of controlled variable PV1 (or of the Ratio)

CO:

Manipulated variable
(Ch and Cc for 3-point PWM signals)

F:

Flow rate (actual value of the Input PV1 for ratio control)

DISPLAY key

SELECT key

Switching over to the parameter definition level by pressing
the key for more than 5 seconds

ENTER key

„Down arrow“ key

„Up arrow“ key

Switching over to the configuration mode by simultaneously
pressing this key and the SELECT key for more than 5 seconds

Confirm set value

Digit selection when setting numeric values

Reducing the value of the manipulated variable (in MANUAL
mode), i.e. reducing the voltage or current (in the case of
standard signals) or the pulse width in the case of PWM signals

Relay 2 on (motor „Reverse“) in the case of 3-step signals
without external feedback

Modifying a numeric value

Increasing the value of the manipulated variable (in MANUAL
mode), i.e. increasing the voltage or current (in the case of
standard signals) or the pulse width in the case of PWM
signals

Relay 1 on (motor „Forwards“) in the case of 3-point step
signals without external feedback

Figure 23: Meanings of operator controls in the process operation level

➤ ➤

DISPLAY

ENTER

0.....9

SELECT

0.....9 ➨