English, Digital industrial controller – Burkert Type 1110 Benutzerhandbuch

Seite 85

Advertising
background image

1110 - 83

DIGITAL INDUSTRIAL CONTROLLER

english

The following table shows the circumstances under which an error is detected with
the various sensor types:

Sensor type

Pt 100

Thermocouple
Type J

Thermocouple
Type K

Thermocouple
Type T

Thermocouple
Type R

Thermocouple
Type S

Standard signal
0 ... 10 V

Standard signal
0 ... 20 mA

Standard signal
4 ... 20 mA

Error occurs in the the following cases

The Pt100 is at a temperature higher than
850 °C

The cable to the Pt100 has a discontinuity

The Pt100 is at a temperature less than
- 200 °C

The cable to the Pt100 has a short-circuit

The thermocouple is at a temperature higher
than 1200 °C

The thermocouple is at a temperature less
than - 200 °C

The thermocouple is at a temperature higher
than 1370 °C

The thermocouple is at a temperature less
than - 200 °C

The thermocouple is at a temperature higher
than 400 °C

The thermocouple is at a temperature less
than 0 °C

The thermocouple is at a temperature higher
than 1760 °C

The thermocouple is at a temperature less
than 0 °C

Das Thermoelement befindet sich auf einer
Temperatur größer als 1760 °C

The thermocouple is at a temperature less
than 0 °C

The connected sensor supplies an output
voltage less than - 0.7 V

The connected sensor supplies an output
voltage less than -0,5 mA

The connected sensor supplies an output
voltage less than 3,5 mA

Value displayed in the
event of an error

+ 850

+ 850

- ***

- ***

+ 1200

- 200

+ 1370

- 200

+ 400

- ***

+ 1760

0

+ 1760

0

PVl
(low scaling value)

PVl
(low scaling value)

PVl
(low scaling value)