4. Design and function

1 Button P

■

Access to the set temperature adjustment

■

Access to the menu items and parameters

■

Input confirmation

2 Button 6

■

Reduction of value being set

■

Selection of individual menu item

■

Go back up one menu level

3 Button 5

■

Increasing value being set

■

Selection of individual menu item

■

Go back up one menu level

4 Button U

Recall the stored set temperatures

5 LED OUT 1

Signals the status of the outputs for the temperature

control

■

If LED OUT 1 is on, the calibrator or the micro

calibration bath is heating

■

If LED OUT 1 is not on, the calibrator or the micro

calibration bath is not heating

6 LED OUT 2

a) Heating instrument

Signals the status of the outputs for the fan control

■

If LED OUT 2 is on, the fan is running at higher

speed

■

If LED OUT 2 is not on, the fan is running at lower

speed

b) Heating and cooling instrument

Signals the status of the outputs for the temperature

control

■

If LED OUT 1 is on, the calibrator or the micro

calibration bath is cooling

■

If LED OUT 1 is not on, the calibrator or the micro

calibration bath is not cooling

7 PV display

■

Indication of the current reference temperature

■

Display of the individual modes, menu items and the

parameters

8 SV display

■

Set temperature display

■

Display of particular parameters in the individual

modes and the menu options

9 LED SET

Flashing signals access to the individual menu items

and parameters