The emergency stop relay SAFE IL1 can be used for:

ƒ

Single and dual-channel protection door monitoring

ƒ

Safety electric circuits according to EN60204 part 1

Safety mats

Assembly and function

S11,S12,S21,S22,S33,S34,S41,S42 S51,S52

Activation- and release contacts

UM-US, 13-14 Safety current circuit (normally open contact)

The activation and input contacts have to be wired according to the intended purpose (s. of " sample
applications " and " assembly and line-up "). For the operation of the device the device must be
connected with the Inline system. Over the Inline bus terminal or a power terminal the voltage supply of
24V/DC is taken over. It lights up the LED "UM".
For the start the terminal S33 with S34 must be bridged with a start button.
Afterwards the contact 13-14 is closed and the segment circuit is switched on. The LED's 1,2 and US
lights up.

If the input set is opened, the safety contacts 13-14 are open and the LED's 1, 2 and US goes out. The
following segment circuit of the Inline system is safety-reality switched off

The device is again activated, if the input sets close and the start button is pressed. The LED's 1 and 2
and US lights up again.
Over the interface to the Interbus Inline local bus can be transferred the device status.

The main circuit is interrupted in the device SAFE IL1.

OPC

Logik/Logic

K2

Start

Not Aus

Emergency stop

K1

Interbus

1 Ul +7V5

2 Uana 24V

3 Ul -

4 Us +24V

5 Um +24V

6 GND

7 FE

Geräteklemmen/
Device terminals

13

14

Inline Klemmen/

Inline terminals