application guide safety relays from riese electronic

page 50

Dual channel safety gate monitoring with

extended control of the release s witch and

with opposite polarity between channels.


If the safety gate switches S1 and S2 are closed,
the output contacts remain unchanged. The
device will be activated by pressing the release
switch. Contacts 13-14 and 23-24 close with a
delay of approximately 100 ms. After opening the
safety gate switches the contacts return to their
normal position without delay.

Suitable up to category 4; SIL3; PLe reachable

Dual channel safety gate monitoring with

automatic activation and with opposite

polarity between channels.


In this application of the device works
automatically, since terminals T11 to T34 are
bridged. If the safety gate switches S1 and S2
are closed, the contacts close with a delay of
approximately 100 ms. After opening the safety
gate switches the contacts return to their normal
position without delay.

Suitable up to category 4; SIL3; PLe reachable

T33

Freigabe /

Release

T12

S 1

T34

T11

T22 T44/

PE

S 2

13

23

T33

T12

S 1

T34

T11

T22 T44/

PE

S 2

13

23