B) safe 2 / safe 2.1 – NORSTAT Safety Relays Benutzerhandbuch

Seite 45

Advertising
background image

application guide safety relays from riese electronic

page 43

START

S34

S33

S22

S21

S12

S11

23

13

Not-

STOP

E-

Halt/

A2(-)

A1(+)

Ub

41

33

START

S34

S33

A2(-)

A1(+)

24V AC/DC

S22

S21

S12

S11

23

13

Not-

STOP

E-

Halt/

Not-

STOP

Halt/

E-

S

ext.

ext.

U

24V AC/DC

START

K

1

ex

t.

K

2

ex

t.

S33

S34 A1(+)

S11

A2(-)

S21

S22

23

ext.

K2

24

K1

ext.

S12

13

14

14

33

41

b) SAFE 2 / SAFE 2.1

(SAFE 2 : with start control)
(SAFE 2.1 : without start control)

Single-channel emergency stop

(without opposite polarity between channels)


By pressing the START button the unit is
activated and contacts 13-14 and 23-24 close.
Pressing the emergency stop will reset the
contacts.

Suitable up to category 2; SIL1; PLd reachable



Dual-channel emergency stop

(with opposite polarity between channels)


For this application the terminal wiring S11, S12,
S21 and S22 is changed. By pressing the START
button the device will be activated and contacts
13-14 and 23-24 close. Pressing the emergency
stop initiates a stop and outputs open
immediately.

Suitable up to category 4; SIL3; PLe reachable




Dual-channel emergency stop with external

contact extension (2 contactors), contact

monitoring and opposite polarity between

channels


This application uses two external contactors with
positive guidance. One normally closed contact of
each external contactors must be connected in
series to the START-button to the terminals S23
and S34. Through the switch S ext. the external
contactors can be operated or turned off at any
time if the SAFE2.. is activated

Suitable up to category 4; SIL3; PLe reachable

Æ

examples for safety mats and contact edges

see operating instructions.


NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866