b) SAFE L.2

(SAFE L.2 with and without start control could be chosen by make a wire bridge between BR1 and BR2)

Dual-channel monitoring of light barrier

(with relay outputs).


By pressing the START button the unit is
activated and contacts 13-14 and 23-24 close. An
interruption of the light beam will reset the
contacts.

Suitable up to category 3; SIL2; PLd reachable





Dual-channel monitoring of light barrier

(with semiconductor outputs and short circuit

monitoring).


By pressing the START button the unit is
activated and contacts 13-14 and 23-24 close.
An interruption of the light beam will reset the
contacts.

Suitable up to category 4; SIL3; PLe reachable

Control such as in application 2 with external

contact extension (2 contactors).


This application uses two external contactors with
positive guidance. One normally closed contact of
each external contactors must be connected in
series to the START-button to the terminals Y1
and Y2. Through the switch S ext. the external
contactors can be operated or turned off at any
time if the SAFEL.. is activated. The external
contactors must connect with separate cable
sheaths.

Suitable up to category 4; SIL3; PLe reachable




BWS-Empfänger

S22

PNP

A1(+)

Y1 Y2

S11

A2(-)

24V AC/DC

START

BR1

S12

BR2

13

33

23

PNP

BWS-Empfänger

PNP

S22

A1(+)

24V AC/DC

START

K

1

ex

t.

K

2

ex

t.

Y1 Y2

A2(-) S11

K1

ext.

ext.

K2

14

14

24

ext.

BR1

S12

BR2

PNP

S

23

13

33

ext.

U

33

23

A1(+)

Y1 Y2

A2(-) S11

24V AC/DC

START

S12

S22

BR1

13

BR2

BWS-Empfänger

NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866

Tel: 973-586-2500 Fax: 973-586-1590 www.norstat.com

Advertising