C) safe 2. 2 – NORSTAT Safety Relays Benutzerhandbuch

Seite 69

Advertising
background image

application guide safety relays from riese electronic

page 65

c) SAFE 2. 2

(without start control, the SAFE 2.2 car only used for safety mats and safety contact edges)

It must be quaranteed that the safety mat or safety contact edge – during load with a standard weight –
does not have a resistance more largely than 1Ω.


Dual-channel application for four-wire safety-

mats with opposite polarity between channels

(with potential free contacts)


In this application the terminals S33 and S34 are
bridged. So this activation of the device works
automatically. Contacts 13-14, 23-24 close after
power is on or after steps off the safety mat.
When the safety mat is stepped on, the contacts
fall back into their normal position without delay.

Suitable up to category 4; SIL3; PLe reachable







Dual-channel application for t wo-wire safety-

mats with opposite polarity between channels

(with potential free contacts)


In this application two connections per channel
are each connected to one of the terminals of the
safety-mat. Terminals S21/S22 and S12/S11 are
connected.
The function is like the application with four wire
safety mats.

Suitable up to category 1; SIL1; PLc reachable

24V AC/DC

S33 S34 A1(+)

S11

S22

A2(-) S21

23

S12 13

A1(+)

S33 S34

A2(-) S21

24V AC/DC

S22

S11

13

S12

23

NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866

Tel: 973-586-2500 Fax: 973-586-1590 www.norstat.com