application guide safety relays from riese electronic

page 47

Y1

Y2

23

A2(-)

A1(+)

13

24V AC/DC

14

24

Start

Not-

STOP

E-

Halt/

Dual channel emergency stop


For this application the normally closed contacts
of the emergency stop button must be
connected in series to the power supply. With
the START button the unit is started. The
contacts 13-14, 23-24 and 33-34 are closed,
contact 41-42 opens. Pressing the emergency
stop will reset the contacts.

In case of protecting wiring ( short current circuit

exclusion ) and regularly tests, for example

during maintenance, up to category 3; SIL2; PLd

reachable.




Dual channel safety gate monitoring


Dual channel safety gate monitoring
If the safety gate switches S1 and S2 are
connected, the output contacts remain
unchanged. The device will
be activated with the Start button. The contacts
13-14, 23-24 and 33-34 are closed, contact 41-
42
be activated with the Start button. The contacts
13-14, 23-24 and 33-34 are closed, contact 41-
42

In case of protecting wiring ( short current circuit

exclusion ) and regularly tests, for example during

maintenance, up to category 3; SIL2; PLd

reachable.



24V AC/DC

*

Y1

Y2

A1(+)

START

S1

S2

A2(-)

13

23

41

33

NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866

Tel: 973-586-2500 Fax: 973-586-1590 www.norstat.com