application guide safety relays from riese electronic

page 61

i) SAFE C1

2-channel e-stop application with monitoring

of start circuit and cross circuit check.


The e-stop switch (safety gate switch resp.)
must be attached to the input circuits (S11/S12,
S21/S22), and the start button must be attached
to the start circuit (S34/S21). The safety outputs
are activated after reclosing the reset circuit
(pressing the start button).

category 4; SIL3; PLe reachable

2-channel safety gate application with auto

start and cross circuit check

.


The safety gate switches must be connected to
the e-stop circuits (S11/S12, S217S22). The
bridge between S34-S11 enables auto start
functionality. After applying power supply the
outputs will be activated immediately.

category 4; SIL3; PLe reachable

1-channel application with monitoring o f

reset circuit.


To enable one-channel functionality S35 and
S11 have to be brigded. The e-stop switch or
safety gate switch resp. of the safety gate must
be connected between terminals S21 and S22.
The start button must be attached to the start
circuit between S21 and S34 (start-circuit input).
category: 2; SIL1; PLd reachable,
3*; SIL2; PLd reachable

1-channel application without monitoring o f

reset circuit.


Equal as the example from the application 3, but
with a bridge between terminals S34 and S11 for
disabling of reset circuit monitoring. At closed
input circuits the outputs are activated after the
connection of supply voltage.
category: 2; SIL1; PLd reachable,
3*; SIL2; PLd reachable





S35

S34

S22

S12

S11

S21

S32

S33

S36 S37




S35

S34

S22

S12

S11

S21

S32

S33

S36 S37



S35

S34

S22

S12

S11

S21

S32

S33

S36

S37




S35

S34

S22

S12

S11

S21

S32

S33

S36

S37




NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866

Tel: 973-586-2500 Fax: 973-586-1590 www.norstat.com

Advertising