NORSTAT Safety Relays Benutzerhandbuch

Seite 76

Advertising
background image

application guide safety relays from riese electronic

page 72

T11

T34/
X1

K21

13

X2

T12

PE/

K22

B2

23

77

Not-
Halt/
E-
STOP

START

T11

K2ext.

T12

K21 T34/

X2

77

K22

PE/

13

23

X1

B2

Not-
Halt/
E-

STOP

K2ext

K1ext

START

Uext

14

14

NAGT
NAGT.1

K1ext.

13

13

Sext

K

Dual channel emergency stop with start

monitoring and opposite polarity between

channels


In this application, the proper turn-on and turn-off
of the start-button is checked. After pressing the
start button contacts 13-14, 23-25 and 77-78
close with 100 ms delay after reopening the start
button. Pressing the emergency stop initiates a
stop and outputs 13-14 and 23-24 open
immediately. The contact 77-78 remains open
during the selected time delay.

up to category …

immediate switching: 4; SIL3; PLe reachable,

time delayed output: 3; SIL2; PLd reachable

Dual channel emergency stop with external

contact expansion (1contactor), contact

monitoring and opposite polarity between

channels


Contact 13-14 closes when the safety relay is
activated by pressing the start button and the
external contactor energizes. Since the external
contactor has contacts with positive guidance the
correct switching of the external contactor can be
controlled through terminals T34/X1 and X2. In
case of welding of one of the external contactors,
the normally open contacts remain open. The
safety relay and the external contactor will not be
activated. In this application the redundancy of
the contactor is not accomplished.

Suitable up to risk category 4 imm ediate open

output

Suitable up to risk category 3 tim

e delayed

output.

Contacts of Kext. : 2.

Dual channel emergency stop with external

contact extension ( 2contactors ), contact

monitoring and opposite polarity between

channels


This application uses two external contactors.
Each normally closed contact of these external
contactors must be connected in series to T34/X1
and X2. The function is similar to application No
5. In this application the demand of redundancy
of the contacts of the external contactors is
accomplished. Through the switch S ext. the
external contactors can be operated or turned off
at any time if the RS-NAGT is activated.

Suitable up to category 2; SIL1; PLd reachable

T11

Not-

Halt/

E-
STOP

K

K21 T34/

X1

X2

T12

ext.

START

ext

ext

K

K

..

K22

PE/

13

B2

23

77

..

NAGT

NAGT.1

14

14

K

13

13

ext

ext

U

U