application guide safety relays from riese electronic

page 18

41

33

START

S34

S33

S22

S21

S12

S11

23

13

Not-

STOP

E-

Halt/

A2(-)

A1(+)

Ub

Emergency stop applications SAFE 4

Single-channel emergency stop (without

opposite between channels).


Pressing the START-button, the unit will be
activated. Contacts 13-14 and close.
Pressing the emergency stop will reset the
contacts.

up to category 4*; SIL3; PLd reachable





Dual-channel emergency stop

(with opposite between channels)


For this application the terminal wiring S11, S12,
S21 and S22 must be used. With the START-
button the device will be activated The contacts
13-14, 23-24 and 33-34 are closed. Pressing the
emergency stop initiates a stop and outputs
open immediately.

up to category 4*; SIL3; PLd reachable






Dual-channel emergency stop with external

contact extension (2 contactors), contact

monitoring and opposite polarity between

channels.


This application uses two external contactors
with positive guidance. One normally closed
contact of each external contactors must be
connected in series to the START-button to the
terminals S33 and S34. Through the switch S
ext. the external contactors can be operated or
turned off at any time if the SAFE 4... is
activated.

up to category 4*; SIL3; PLd reachable






41

33

START

S34

S33

A2(-)

A1(+)

24V AC/DC

S22

S21

S12

S11

23

13

Not-

STOP

E-

Halt/

Not-

STOP

Halt/
E-

S

ext.

ext.

U

24V AC/DC

START

K

1

ex

t.

K

2

ex

t.

S33

S34 A1(+)

S11

A2(-)

S21

S22

23

ext.

K2

24

K1

ext.

S12

13

14

14

33

41