application guide safety relays from riese electronic

page 58

Dual channel emergency stop with external

expansion of contacts (t wo contactors),

contact monitoring and opposite polar ity

between channels with RS-NAGMP.1


This application uses dual external contactors.
Each normally closed contact of these external
contactors must be connected in series to X1 and
X2. The function is similar to application no. 5.
In this application the demand of redundancy of
the contacts of the external contactors is
accomplished. Through the switch S ext. the
external contactors can be operated or turned
off at any time if the RS-NAGMP is activated.

Suitable up to risk category:

- Safety outputs of RS-NAGMP.1 : 4; SIL3; PLe

reachable

- Contacts of K1ext./K2ext.:

3; SIL2; PLd reachable

(with separate sheathed cable)





Dual channel protection door monitoring with

RS-NAGMP.1 (manual and automatic start)


With the dual channel protection door monitoring
terminals T21 und PE as well as X1 und X2 have
to be bridged. If using the automatic start, you
have to bridge the terminals T33 and T34.
With automatic start the contacts closes with a
delay of approximately 100ms.
In this application a fault in the protection door
monitoring switch will be detected

Suitable

up to category 3; SIL2; PLd reachable





Dual channel protection door monitoring with

opposit polarity between channels with RS-

NAGMP.1 (manual and automatic start)


In this application terminals T11 and T21 as well
as X1 and X2 have to be bridged. If using the
automatic start, you have to bridge the terminals
T33 and T34.
With automatic start the contacts closes with a
delay of approximately 100ms.
The function is similar to application no 14.

Suitable up to category 4; SIL3; PLe reachable




T23

S

ta

rt

T12

T11 T33

S2

X2

T34

X1

T12

T22

T21

S1

T23

S

ta

rt

T12

T11 T33

S1

S2

X2

T34

X1

T21

T12

T22

S1

T22

X1

S

TA

R

T

T33

T11

T34

K1ext

Not-

Halt/

E-Stop

T21

X2

T12

13

13

T12

T23

ext

K

..

ext

Uext

U

K2ext

ext

K

14

NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866

Tel: 973-586-2500 Fax: 973-586-1590 www.norstat.com

Advertising