Safe cz, Combination examples – NORSTAT Safety Relays Benutzerhandbuch

Seite 79

Advertising
background image

application guide safety relays from riese electronic

page 75

4 Product application for

- two hand control relays

Impulse diagram for two hand control

relays type III (III a, III b, III c)

a)

SAFE CZ

13-14

23-24

S2

on

power

off

S1

0,5s

<-->

0,5s

<-->

0,5s

<-->

0,5s

<-->

Two-hand application type IIIC with checking of synchroneous

actuation.

Both keys consist of a n/o and a n/c switch. The first pushbutton
switches output S11 from input S22 to S12 and the second one
switches output S21 from input S12 to S22. Bridge S21-S32 is
configuring the device to work without AND combination (stand alone).

The feedback control must be closed either by a n/c contact of an
expanding relay or by a bridge between.

category 4; SIL3; PLe reachable

S32

S12

S11

S34

S21

Kext

A1

S33 S35 S36 S37 34

+24VDC

S21 S22

44

14

24

A2

0VDC

Two-hand application type IIIC with AND-combination.

The function is the same as in the 1st application, except the open
input S32 configures the device without AND-combination. It is
attached to the input S33. Allowed are the outputs 14, 24 of all family C
devices.

category 4; SIL3; PLe reachable

S32

S12

S11

S34

Kext

A1

S35 S36 S37

34

+24VDC

S21 S22

44

A2

0VDC

"UND"

S33

14

24

Two-hand application type II without monitoring of synchronous

actuation.

The function is the same as in the 1st application, except the bridge
S11-S35 configures the device for a function type II without control of
synchronous actuation. Reactivation of the safety outputs 14, 24, 34,
44 is only possible when the two push-buttons are disengaged
synchronous a new actuation.

category 3; SIL2; PLd reachable

S32

S12

S11

S34

S21

Kext

A1

S33 S36 S37 14

24

+24VDC

S21 S22

34

A2

0VDC

44

S35

Combination examples

Contact expansion over the emergency stop circles.

If the device

A switches off (the outputs have low potential), the

contactors K1 and K2 will de-energise. Device

B switches off its

safety outputs via its own e-stop circuits, as well, and though
contactors K3, K4 de-energize.

Up tocategory 4; SIL3; PLe reachable

S32

S33

24

S11

K1

K2

K3

K4

14

A

B

24
14

safety

input

safety

input