application guide safety relays from riese electronic

page 57

Single channel emergency stop with RS-

NAGMP.1


For this application terminals T12 and T22, T21
and PE as well as X1 and X2 have to be
bridged. The device will be activated by
pressing the start button. Contacts 13-14, 23-
24, 33-34 are closing and contact 41-42 opens.
By activating the OFF button or the emergency
stop button the contacts return to their normal
position. In this application the demand of
redundancy in the switch is not accomplished.

Suitable

up to category 2; SIL1; PLd reachable





Dual channel emergency stop with RS-

NAGMP.1


Using the dual channel emergency stop button
the terminals T12 and T22 are not bridged. The
function is similar to application No. 1.
In this application a fault in the emergency stop
button will be detected.

Suitable

up to category 3; SIL2; PLd reachable





Dual channel emergency stop with opposite

polarity between channels with RS-

NAGMP.1


Using this application the terminals T11 and
T21 as well as X1 and X2 have to be bridged.
The device will be activated by pressing the
start button. Contacts 13-14, 23-24, 33-34 are
closing and contact 41-42 opens. By pressing
the emergency stop button all contacts return
to their normal position.

Suitable up to category 4; SIL3; PLe reachable














































T11

T33

S

TA

R

T

X1

T34

X2

Not-Halt /

E-STOP

T22

T12

T12

T21

T23

T11

T33

S

TA

R

T

X1

T34

X2

Not-

Halt/

T22

T12

T12

T21

T23

T11

T33

S

TA

R

T

X1

T34

X2

Not-

Halt/

T22

T12

T12

T21

T23

NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866

Tel: 973-586-2500 Fax: 973-586-1590 www.norstat.com

Advertising