C) safe 4 / safe 4.1 – NORSTAT Safety Relays Benutzerhandbuch

Seite 47

Advertising
background image

application guide safety relays from riese electronic

page 45

41

33

START

S34

S33

S22

S21

S12

S11

23

13

Not-

STOP

E-

Halt/

A2(-)

A1(+)

Ub

c) SAFE 4 / SAFE 4.1

(SAFE 4.1: without start control)

Single-channel emergency stop

(without opposite polarity between channels)


By pressing the START button the unit is
activated and contacts 13-14 and 23-24 close.
Pressing the emergency stop will reset the
contacts.

Suitable up to category 4; SIL3; PLd reachable

when using restricted guided switches and lend

the wiring in separate counted cables.


Dual-channel emergency stop

(with opposite polarity between channels)


For this application the terminal wiring S11, S12,
S21 and S22 is changed. By pressing the START
button the device will be activated and contacts
13-14 and 23-24 close. Pressing the emergency
stop initiates a stop and outputs open
immediately.

Suitable up to category 4; SIL3; PLe reachable



Dual-channel emergency stop with external

contact extension (2 contactors), contact

monitoring and opposite polarity between

channels


This application uses two external contactors with
positive guidance. One normally closed contact of
each external contactors must be connected in
series to the START-button to the terminals S33
and S34. Through the switch S ext. the external
contactors can be operated or turned off at any
time if the SAFE4 / SAFE4.1 is activated.

Suitable up to category 4; SIL3; PLe reachable



24V AC/DC

S33 S34 A1(+)

START

S11

A2(-)

S21

S22

23

S12

13

33

41

NOT-

STOP

AUS/
E-

S11

START

K

1

ex

t.

K

2

ext.

S33

S34

A1(+) A2(-)

S21

S22

24V AC/DC

NOT-

STOP

AUS/
E-

K1

ext.

ext.

K2

23

24

S12

13

14

14

33

41

S

ext.

ext.

U