6 expansion modules – NORSTAT Safety Relays Benutzerhandbuch

Seite 37

Advertising
background image

application guide safety relays from riese electronic

page 35

6 Expansion modules

Expansion modules are used to increase the number of safety outputs and can be connected to a normal
safety relay. The number of expansion modules connected to a safety relay should not exceed 6. There are
two possible versions available :

type

specialties

safety output

auxiliary outputs

opposite polarity

between channels

category

SAFE IL2

63 mm housing

5

1

-

4

SAFE X4 / 4.1

22,5 mm housing

4

1

selectable

4

NAGX 5

45 mm housing

5

1

selectable

4


SAFE IRZ.2

22,5 mm housing

1 changer


1

selectable

suitable up to risk

category max. 4

control dependent


SAFE IRZ.2 / RS – NAGX 5 : conversion of semiconductor output to relay output
(RS-NAGU, NAGU.1, RS- NAGU.1b, RS-NAGU.12)

Function diagram SAFE X4
















A transformer is used for the following voltages:
48, 110-127, 230VAC.
A electrical fuse is used instead of an transformator with the 24VAC/DC voltage device.
Æ

some applications as well as expansions with contactors are shown on page 132.

elektr. Sicherung

Transformator /

electr. Fuse

transformer

Überwachungslogik /

-

AC

A1

K1

Y2

DC

+

K2

14

24

34

44

Y1

Controller Logic

A2

U1 U22

K1

K21

13

23

33

43

NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866

Tel: 973-586-2500 Fax: 973-586-1590 www.norstat.com