background image

application guide safety relays from riese electronic

page 140

Product Application for SAFE ILL



Dual-channel monitoring of light barrier or

light curtain

(with relay outputs).


After pressing the START-button, the device is
active. The security contact 13-14 will close. An
interruption of the light beam will reset the
contacts.

Suitable up to category 1,PLc, SIL1 reachable


Dual-channel monitoring of light barrier or

light curtain (with semiconductor outputs

and short circuit monitoring).


After pressing the START-button, the device is
active. The security contact 13-14 will close. An
interruption of the light beam will reset the
contacts.

Suitable up to

category 4, PLe, SIL 3 reachable



Dual-channel monitoring of light barrier or

light curtain (with semiconductor outputs

and short circuit monitoring) and automatical

start.


Bridge the terminals S33-S34. The device will
now start automatically.
The security contact 13-14 will close. An
interruption of the light beam will reset the
contacts.
After the end of interruption, the device start
automatically and close the security contact.

Suitable up to

category 4, PLe, SIL 3 reachable


S33

S33

S11

S12

S22

S41

S42

13

14

START

Empfänger/

Receiver

S33

S33

S11

S12

S22

S41

S42

13

14

START

Empfänger/

Receiver

GND

PNP

PNP

GND

S33

S33

S51

S12

S22

S41

S42

13

14

Empfänger/

Receiver

GND

PNP

PNP

GND

S52

NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866