Safe z, C) safe z, D) rs-nagz – NORSTAT Safety Relays Benutzerhandbuch

Seite 81: Rs-nagz, Connection plan

Advertising
background image


application guide safety relays from riese electronic

page 77

T44

U ext

K2ext

.

X1

T11 T34

K1

ex

t.

S2

RS-NAGZ

T12

X2

T22

S1

24

42

41

14

13

24

23

K1ext.

K2ext.

13

14

S ext

23

c) SAFE Z

Connection plan

Two hand control relays SAFE Z according to
BG,
section iron and metal III ZH 1/456 (o2.78) and
DIN EN 574 (02.97) for type I - III c.

Suitable up to

category 4; SIL3; PLe reachable

Operate mode

There must be installed an auxiliary voltage at
the terminals A1 and A2 in order to operate the
device.
Then power LED starts illuminating. By pressing
the button S1 simultaneously to S2 the safety
outputs 13-14 and 23-24 will switch. This causes
an machine connected to the safety outputs gets
able to start.
Attention: The simultaneous of the two hand
control button S1 and S2 has to be smaller 0,5
sec.
If one or both buttons released, the outputs 13-1
simultaneous and 23-24 will open
immediately.Only after releasing S1 and S2 a
new cycles can be started. If the simultaneous
time will be bigger than 0,5 sec the outputs will
not be released. The outputs 13-14 and 23-24
stay open. The machine cannot be started.
It is possible to connect machine-release-circuits
at the terminals S21 and Y2.
The contact extension have to get export.





S11

SAFE Z

A2(-)

A1(+)

S1

S2

24V AC/DC

S21

S22

Y2

d) RS-NAGZ

Connection plan

Two hand control relays RS-NAGZ according to
BG, section iron and metal III ZH 1/456 (o2.78)
and DIN EN 574 (02.97) for type I - III b.

Suitable up to category 3; SIL2; PLd reachable


















NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866

Tel: 973-586-2500 Fax: 973-586-1590 www.norstat.com

Advertising