application guide safety relays from riese electronic

page 73

Single channel protection door monitor ing

with opposite polarity between channels


If the safety switch S1 is closed the output
contacts remain unchanged. The device will be
activated by pressing the release switch.
Contacts 13-14, 23-24 and 77-78 close with a
delay of approx. 100 ms. While opening the
safety switch the contacts return to their normal
position without delay. The contact 77-78 remains
open during the selected time delay.
With this application the requirement of
redundancy in the protection door switch is not
accomplished.

Suitable up to category 2; SIL1; PLd reachable

Dual channel protection door mo nitoring

without opposite polarity between channels


In this application the terminals K22 and K12 are
not bridged. The function is similar to application
No. 7. In this application a fault in the safety
switch will be detected.

Suitable up to category 3; SIL2; PLd reachable






Dual channel protection door monitoring with

opposite polarity between channels


If the safety switches S1 and S2 are closed, the
output contacts remain unchanged. Through a
short operation of the release switch contacts 13-
14, 23-24 and 77-78 close after a delay of
approximately 100 ms.
After opening the safety switches the contacts 13-
14 and 23-24 return to their normal position
without delay. The contact 77-78 remains open
during the selected time delay.

up to category ...

immediate switching: 4; SIL3; PLe reachable,

time delayed output: 3; SIL2; PLd reachable

T12

T11

X2

T34/

X1

K22

S1

S1

77

K21 PE/

B2

13

23

Fr

ei

ga

be

/

re

le

as

e

T11 T34/

X1

X2

K22

T12

S1

13

K21 PE/

B2

23

77

Fr

ei

ga

be

/

re

le

as

e

S2

T12

X1

K21

T11

T34/

X2

S1

B2

PE/

K22

S2

13

23

77

Freigabe/

release